北市區(qū)SANIL開關(guān)SB-31L,5m,Mos,Relay,2m,中山立訊電氣有限公司工廠直售韓國SYM(ShinYeong Mechatronics )電磁閥
BP-KV100 BP-KV100B BP-KV190 BP-KV200 BP-KV200B BP-KV290 BP-KV300 BP-KV300B BP-KV390 CA2-V1 CA2-V2 CA2-V4 CA2-V4-10 CA2-V4-15 CA2-V4-30 CA2-V4-6 EP-KV100 EP-KV100B KV100B-BASE KV100-G KV100-GS KV110-1E-C4 KV110-1E-C6 KV110-1E-M5 KV110-2E-C4 KV110-2E-C6 KV110-2E-M5 KV110-2L-M5 KV110-3E-C4 KV110-3E-C6 KV110-3E-M5 KV110-3L-C4 KV110-3L-C6 KV110-3L-M5 KV110-3P-C4 KV110-3P-C6 KV110-3P-M5 KV110-4E-C4 KV110-4E-C6 KV110-4E-M5 KV110-4E-M5-X3 KV110-4EN-C4 KV110-4EN-M5 KV110-4ES-C4 KV110-4ES-M5 KV110-4EZ-C4 KV110-4EZ-M5 KV110-4L-C4 KV110-4L-C6 KV110-4L-M5 KV110-4P-C4 KV110-4P-C6 KV110-4P-M5 KV110-4PN-C4 KV110-4PN-C6 KV110-4Q-C4 KV110-4Q-C6 KV110-4Q-M5 KV110-6E-M5 KV110B-1E KV110B-1E-01 KV110B-2E KV110B-2E-01 KV110B-3E KV110B-3E-01 KV110B-3P KV110B-4E KV110B-4E-01 KV110B-4L KV110B-4L-01 KV110B-4P KV110B-4P-01 軟啟動器只是改變電源電壓,相當于降壓起動器。變頻器要比軟啟動器復雜得多,價格也貴得多。變頻器也有軟啟動功能,是通過改變電源頻率實現(xiàn)。高壓啟動器和低壓啟動器的區(qū)別軟啟動器主回路采用晶閘管,通過逐步改變晶閘管的導通角來抬升電壓,完成啟動過程,這是軟啟動器的基本原理。在低壓軟啟動器市場,產(chǎn)品繁多,但是高壓軟啟動器產(chǎn)品還是比較少。高壓軟啟動器與低壓軟啟動器基本原理一樣,但是高壓軟啟動器與低壓軟啟動器相比,有些地方存在著其特殊性:高壓軟啟動器在高壓環(huán)境下工作,各種電氣元器件的絕緣性能一定要好,電子芯片的抗干擾能力要強。高壓軟起動器組成電氣柜時,電氣元器件的布局以及與高壓軟啟動器與其它電氣設(shè)備的連接也是非常重要的。KV110B-4Q KV110B-4Q-01 KV120-1E-M5 KV120-2E-C4 KV120-2E-C6 KV120-2E-M5 KV120-3E-C4 KV120-3E-C6 KV120-3E-M5 KV120-3P-C4 KV120-3P-C6 KV120-3P-M5 KV120-4E-C4 KV120-4E-C6 KV120-4E-M5 KV120-4EN-M5 KV120-4L-C4 KV120-4L-C6 KV120-4L-M5 KV120-4P-C4 KV120-4P-C6 KV120-4P-M5 KV120-4PN-C4 KV120-4Q-C4 KV120-4Q-C6 KV120-4Q-M5 KV120-6E – ??? KV120-6E-??? KV120B-1E KV120B-1E-01 KV120B-3E KV120B-3P KV120B-4E KV120B-4E-01 KV120B-4L KV120B-4L-01 KV120B-4P KV120B-4P-01 KV120B-4Q KV120B-4Q-01 KV120B-6E KV130-1E-C6 KV130-1E-M5 KV130-2E-M5 KV130-3L-C4 KV130-3L-C6 KV130-3L-M5 KV130-3P-C4 KV130-3P-M5 KV130-4E-C4 KV130-4E-C6 KV130-4E-M5 KV130-4EN-C4 KV130-4L-C4 KV130-4L-C6 KV130-4L-M5 KV130-4P-C4 KV130-4P-C6或可采用高速可控硅(晶閘管)。關(guān)于連續(xù)峰值開路電壓VDRM在電源不正常的情況下,可控硅(晶閘管)兩端的電壓會超過連續(xù)峰值開路電壓VDRM的值,此時可控硅(晶閘管)的漏電流增大并擊穿導通。如果負載能允許很大的浪涌電流,那么硅片上局部的電流密度就很高,使這一小部分先導通。導致芯片燒毀或損壞。另外白熾燈,容性負載或短路保護電路會產(chǎn)生較高的浪涌電流,這時可外加濾波器和鉗位電路來防止尖峰(毛刺)電壓加到雙向可控硅(晶閘管)上[2]。
KV130-4P-M5 KV130-4Q-C4 KV130-4Q-C6 KV130-4Q-M5 KV130B-1E KV130B-2E KV130B-3E KV130B-4E KV130B-4E-01 KV130B-4L KV130B-4L-01 KV130B-4P KV130B-4P-01 KV130B-4Q KV130B-4Q-01 KV130B-6E KV140-1E-M5 KV140-2E-C4 KV140-2E-M5 KV140-3E-C6 KV140-3E-??? KV140-4E-C4 KV140-4E-C6 KV140-4E-M5 KV140-4L-C4 KV140-4L-C6 KV140-4L-M5 KV140-4P-C4 KV140-4P-C6 KV140-4P-M5 KV140-4Q-C4 KV140-4Q-C6 KV140-4Q-M5 KV140B-4E KV140B-4E-01 KV140B-4L KV140B-4L-01 KV140B-4P KV140B-4P-01 KV140B-4Q KV140B-4Q-01 KV150-2E-M5 KV150-2E-??? KV150-4E-C4 KV150-4E-C6 KV150-4E-M5 KV150-4L-C4 KV150-4L-C6 KV150-4L-M5 KV150-4P-C4 KV150-4P-C6
中山立訊電氣有限公司工廠直售韓國SYM(ShinYeong Mechatronics )電磁閥
KV150-4P-M5 KV150-4Q-C4 KV150-4Q-C6 KV150-4Q-M5 KV150B-4E KV150B-4E-01 KV150B-4L KV150B-4L-01 KV150B-4P KV150B-4P-01 KV150B-4Q KV150B-4Q-01 KV200B-BASE KV200-G KV200-GS KV200-S KV210-1E-01 KV210-1E-C4 KV210-1E-C6 KV210-1E-C8 KV210-1L-01 KV210-1L-C4 KV210-1L-C6 KV210-2E-01 KV210-2E-C4 KV210-2E-C6 KV210-2E-C8 KV210-2L-01 KV210-2L-C4 KV210-2L-C6 KV210-3E-01 KV210-3E-C4 KV210-3E-C8 KV210-3E-V6 KV210-3P-01 KV210-3P-C4 KV210-3P-C6 KV210-3P-C8 KV210-4E-01 KV210-4E-C4 KV210-4E-C6 KV210-4E-C8 KV210-4EN-01 KV210-4L-01 KV210-4L-C4 KV210-4L-C6 KV210-4P-01 KV210-4P-C4 KV210-4P-C6 KV210-4Q-01 KV210-4Q-C4 KV210-4Q-C6 KV210B-1E KV210B-1E-02 KV210B-1L KV210B-2E KV210B-2E-02 KV210B-2L KV210B-2L-02 KV210B-3E KV210B-4E它是旋轉(zhuǎn)180°后的二次電流向量與一次電流向量之間的相位差。規(guī)定二次電流向量超前于一次電流向量δ為正值,反之為負值,用分(’)為計算單位。2.10熱穩(wěn)定及動穩(wěn)定倍數(shù):電力系統(tǒng)故障時,電流互感器受到由于短路電流引起的巨大電流的熱效應和電動力作用,電流互感器應該有能夠承受而不致受到破壞的能力,這種承受的能力用熱穩(wěn)定和動穩(wěn)定倍數(shù)表示。熱穩(wěn)定倍數(shù)是指熱穩(wěn)定電流1s內(nèi)不致使電流互感器的發(fā)熱超過允許限度的電流與電流互感器的額定電流之比。動穩(wěn)定倍數(shù)是電流互感器所能承受的電流瞬時值與其額定電流之比。類型區(qū)分編輯按用途分類按照用途不同,電流互感器大致可分為兩類[4]:測量用電流互感器(或電流互感器的測量繞組):在正常工作電流范圍內(nèi)。 KV210B-4E-02 KV210B-4L KV210B-4L-02 KV210B-4P KV210B-4P-02 KV210B-4Q KV210B-4Q-02 KV210B-6P KV210B-6P-02 KV220-1E-01 KV220-1E-C6 KV220-2E-01 KV220-2E-C4 KV220-2E-C6 KV220-2L-01 KV220-2L-C4 KV220-2L-C6 KV220-3E-01 KV220-3E-C4 KV220-3E-C6 KV220-4E-01 KV220-4E-C4 KV220-4E-C6 KV220-4E-C8 KV220-4EN-01 KV220-4L-01 KV220-4L-C4 KV220-4L-C6 KV220-4P-01 KV220-4P-C4 KV220-4P-C6 KV220-4Q-01 KV220-4Q-C4 KV220-4Q-C6 KV220B-1E KV220B-2E KV220B-4E KV220B-4E-02 KV220B-4L KV220B-4L-02 KV220B-4P管壓降(通態(tài)平均電壓)為0.6---0.7V的普通型可控硅。綜上所述,小結(jié)如下:(1)可控硅一般做成螺栓形和平板形,有三個電極,用硅半導體材料制成的管芯由PNPN四層組成(2)可控硅由關(guān)斷轉(zhuǎn)為導通必須同時具備兩個條件:(1〕受正向陽極電壓;(2)受正向門極電壓。(3)可控硅導通后,當陽極電流小干維持電流In時.可控硅關(guān)斷。(4)可控硅的特性主要是:1.陽極伏安特性曲線,2.門極伏安特性區(qū)。(5)應在額定參數(shù)范圍內(nèi)使用可控硅。選擇可控硅主要確定兩個參致:主要參數(shù)編輯電流⒈額定通態(tài)電流(IT)即穩(wěn)定工作電流,俗稱電流。常用可控硅的IT一般為一安到幾十安。⒉反向重復峰值電壓(VRRM)或斷態(tài)重復峰值電壓(VDRM)。 KV220B-4P-02 KV220B-4Q KV220B-4Q-02 KV230-1E-01 KV230-1E-C4 KV230-1E-C6 KV230-2E-02 KV230-2E-C4 KV230-2E-C6 KV230-3E-01 KV230-3E-C4 KV230-3E-C6 KV230-3P-01 KV230-3P-C4 KV230-3P-C6 KV230-4E-01 KV230-4E-C4 KV230-4E-C6 KV230-4E-C8 KV230-4L-01 KV230-4L-C4 KV230-4L-C6 KV230-4P-01 KV230-4P-C4 KV230-4P-C6 KV230-4Q-01 KV230-4Q-C4 KV230-4Q-C6 KV230B-1E KV230B-1E-02 KV230B-2E KV230B-4E KV230B-4E-02 KV230B-4L KV230B-4L-02 KV230B-4P KV230B-4P-02 KV230B-4Q KV230B-4Q-02 KV240-1E-01 KV240-1E-C4 KV240-1E-C6 KV240-2E-01 KV240-2E-C4 KV240-2E-C6 KV240-4E-01 KV240-4E-C4 b)當I/Is>2時,平均誤差不大于5%+30ms。整定方法起動電流整定:起動電流整定開關(guān)為左一組撥碼開關(guān)(共兩個),左面一個表示1A級,右面一個表示0.1A級。若其值為5和6,則其整定值為5.6A。注意其范圍為無輔助電壓產(chǎn)品2-9.9A,級差是0.1A級。反時限特性曲線K值整定:K值整定開關(guān)為左第三組撥碼開關(guān)(共二個),左邊一個為表示1級;右邊一個表示0.1級。本產(chǎn)品K值整定范圍為0.1~9.9,(舉例)比如其值設(shè)定為5.0,過流動作值設(shè)定為5.0,輸入實際電流為30A時那么它的延時時間為13.5秒,但其速斷倍數(shù)值應設(shè)定為6倍以上。速動倍數(shù)整定:速動倍數(shù)選擇開關(guān)為左第二組撥碼開關(guān)。
所以對大容量變頻器更加有效。還可以用隔離板把本體和散熱器隔開,使散熱器的散熱不影響到變頻器本體。這樣效果也很好。注意:變頻器散熱設(shè)計中都是以垂直安裝為基礎(chǔ)的,橫著放散熱會變差的!冷卻風扇一般功率稍微大一點的變頻器,都帶有冷卻風扇。同時,也建議在控制柜上出風口安裝冷卻風扇。進風口要加濾網(wǎng)以防止灰塵進入控制柜。注意控制柜和變頻器上的風扇都是要的,不能誰替代誰。其他關(guān)于散熱的問題在海拔高于1000m的地方,因為空氣密度降低,因此應加大柜子的冷卻風量以改善冷卻效果。理論上變頻器也應考慮降容,1000m每-5%。但由于實際上因為設(shè)計上變頻器的負載能力和散熱能力一般比實際使用的要大,所以也要看具體應用。比方說在1500m的地方。