摘要:近年來(lái),隨著國(guó)內(nèi)外大批的太陽(yáng)能光伏電站的建立和并網(wǎng)發(fā)電,作為光伏發(fā)電的關(guān)鍵設(shè)備光伏并網(wǎng)逆變器具有廣闊的市場(chǎng)前景。本文主要介紹WEINVIEW觸摸屏在太陽(yáng)能光伏并網(wǎng)逆變器中的應(yīng)用。在這個(gè)系統(tǒng)中,觸摸屏和逆變控制器通信,完成相關(guān)的數(shù)據(jù)采集,資料的保存,報(bào)警信息的登錄,圖文并茂顯示逆變器運(yùn)行參數(shù)和實(shí)時(shí)狀態(tài),并通過(guò)485或以太網(wǎng)和上位計(jì)算機(jī)進(jìn)行遠(yuǎn)程通訊,實(shí)現(xiàn)整個(gè)并網(wǎng)電站的實(shí)時(shí)監(jiān)控和調(diào)配。
Abstract:In recent years, with the large number of solar photovoltaic power plants establishing and grid connection generation at home and abroad , As the key equipment in PV power generation, photovoltaic grid-connected inverter has broad market prospect. The introduction in this paper focus on the application of WEINVIEW touch screen in photovoltaic grid-connected inverter. In this system, touch screen communicates with the microcontroller, and completes related data acquisition, inbation saving, alarm inbation loginning, and shows operating beters and real-time status of inverter on the touch screen , Remote communication with the host computer through the RS485 or the Ethernet, At last to achieve real-time monitoring and deploy of the entire grid station.
關(guān)鍵字:光伏 逆變器 觸摸屏 DSP
Keywords: Photovoltaic Inverter Touch screen DSP
一:引言
隨著全球氣候變暖,傳統(tǒng)的燃料資源日趨枯竭,世界各國(guó)都把目光投向了可再生能源,希望可再生能源改變?nèi)祟惖哪茉唇Y(jié)構(gòu),維持長(zhǎng)遠(yuǎn)的可持續(xù)發(fā)展。在可再生能源中,太陽(yáng)能以其獨(dú)有的優(yōu)勢(shì)而成為人們關(guān)注的焦點(diǎn)。太陽(yáng)能是取之不盡、用之不竭、無(wú)污染的綠色能源。世界各國(guó)都在投入巨資建設(shè)大規(guī)模的太陽(yáng)能發(fā)電站。我國(guó)在光伏研究和產(chǎn)業(yè)方面也取得了較快的進(jìn)展,2006年1月1日實(shí)施的《可再生能源法》,標(biāo)志著太陽(yáng)能發(fā)電已納入我國(guó)的能源發(fā)展規(guī)劃之中。根據(jù)2007年9月發(fā)布的《可再生能源中長(zhǎng)期發(fā)展規(guī)劃》,2020年,我國(guó)太陽(yáng)能發(fā)電設(shè)備累計(jì)裝機(jī)容量將達(dá)到2000MW 。
太陽(yáng)能光伏并網(wǎng)逆變器是整個(gè)光伏發(fā)電系統(tǒng)中最為關(guān)鍵的設(shè)備之一,它是把太陽(yáng)能電池板產(chǎn)生的直流電能轉(zhuǎn)換為交流電能的設(shè)備,運(yùn)行過(guò)程中需要多個(gè)參數(shù)進(jìn)行監(jiān)測(cè)、計(jì)算、顯示、記錄、保存、報(bào)警等處理,需要和上位計(jì)算機(jī)、逆變控制器進(jìn)行通訊,實(shí)現(xiàn)數(shù)據(jù)交換。本文主要講述WEINVIEW觸摸屏在太陽(yáng)能光伏并網(wǎng)逆變器中的應(yīng)用。
二:系統(tǒng)原理和方案設(shè)計(jì)
太陽(yáng)能光伏并網(wǎng)逆變器是把太陽(yáng)能電池板通過(guò)光伏效應(yīng)產(chǎn)生的直流電能進(jìn)行逆變,轉(zhuǎn)換成同電網(wǎng)同頻率、同相位的交流電,接入電網(wǎng)對(duì)外進(jìn)行輸電。逆變器運(yùn)行中要把測(cè)量的實(shí)時(shí)參數(shù)送給觸摸屏,進(jìn)行顯示、記錄等操作,也可和上位機(jī)通訊進(jìn)行遠(yuǎn)程監(jiān)控功能。系統(tǒng)原理圖如下圖所示:
三:WEINVIEW畫面設(shè)計(jì)要求
本系統(tǒng)采用WEINVIEW MT8010IV2型號(hào)觸摸屏,高品質(zhì)10”寬屏設(shè)計(jì),LED背光模組,采用400MHz RISC CPU,使運(yùn)行速度更快,內(nèi)置電源隔離保護(hù)器,提高了產(chǎn)品的抗干擾能力,適應(yīng)復(fù)雜環(huán)境下運(yùn)行。多種標(biāo)準(zhǔn)的通訊接口和網(wǎng)絡(luò)協(xié)議,方便用戶使用。大容量的數(shù)據(jù)存儲(chǔ)功能,外接USB閃存和SD卡存儲(chǔ)資料,滿足逆變器運(yùn)行過(guò)程中產(chǎn)生的海量數(shù)據(jù)信息。
1,觸摸屏主界面設(shè)計(jì)
主界面顯示逆變器運(yùn)行的各種運(yùn)行參數(shù):PV電壓、PV電流、A、B、C三項(xiàng)交流電壓和電流、功率因數(shù)、電網(wǎng)頻率、輸出功率、日發(fā)電量、總發(fā)電量、CO2減排量等,逆變器運(yùn)行狀態(tài)指示,實(shí)時(shí)時(shí)間,以及其他操作菜單。下圖分別是主界面的中英文顯示菜單。
2,功率曲線顯示功能設(shè)計(jì)
逆變器運(yùn)行中實(shí)時(shí)功率是一個(gè)非常重要的參數(shù),功率曲線圖反映逆變器運(yùn)行的歷史運(yùn)行情況和趨勢(shì)。逆變器功率曲線顯示由三條宏指令完成:
A:逆變器運(yùn)行的實(shí)時(shí)功率計(jì)算MT8010IV2觸摸屏 + 三菱PLC 南京制菱實(shí)業(yè)進(jìn)入光伏行業(yè)
B:實(shí)時(shí)功率的RW_A保存
C:功率曲線顯示
實(shí)時(shí)功率計(jì)算宏指令如下:
macro_command main()
short i,v
int pa,pb,pc
GetData(v, "Local HMI", LW, 2, 1) //A相電壓
GetData(i, "Local HMI", LW, 3, 1) //A相電流
pa=v
pa=pa*i //相乘
GetData(v,"Local HMI", LW, 4, 1) //B相電壓
GetData(i,"Local HMI", LW, 5, 1) //B相電流
pb=v
pb=pb*i //相乘
GetData(v, "Local HMI", LW, 6, 1) //C相電壓
GetData(i, "Local HMI", LW, 7, 1) //C相電流
pc=v
pc=pc*i //相乘
pc=pa+pb+pc //A相B相C相功率之和
SetData(pc, "Local HMI", LW, 300, 1)//存儲(chǔ)在LW300中
end macro_command
功率計(jì)算宏指令1秒鐘循環(huán)執(zhí)行一次,把三相輸出功率之和保存在LW300單元中。
功率存儲(chǔ)宏指令如下:
macro_command main()
short day,hour,minute
int add,x
GetData(minute, "Local HMI", LW, 9018, 1) //讀取分
GetData(hour, "Local HMI", LW, 9019, 1) //讀取時(shí)
GetData(day, "Local HMI", LW, 9020, 1) //讀取日
add=day*1440+hour*60+minute //當(dāng)前功率保存地址計(jì)算
GetData(x, "Local HMI", LW, 300, 1) //實(shí)時(shí)功率
SetData(x, "Local HMI", RW_A, add, 1) //保存在RW_A中
end macro_command
功率存儲(chǔ)宏指令1分鐘循環(huán)執(zhí)行一次,根據(jù)當(dāng)前時(shí)間計(jì)算出功率存儲(chǔ)的地址,把當(dāng)前功率值保存在此地址中。實(shí)時(shí)保存地址=日*1440+時(shí)*60+分。每分鐘保存一次,功率數(shù)據(jù)占一個(gè)單元(功率數(shù)據(jù)保存是從0時(shí)開始的全天數(shù)據(jù))。
XY軸曲線顯示宏指令如下:
macro_command main()
short i,add,add0,day
int z
GetData(day, "Local HMI", LW, 9020, 1) //讀取當(dāng)前日期
i=3
SetData(i, "Local HMI", LW, 402, 1) //XY曲線顯示控制單元
i=720
SetData(i, "Local HMI", LW, 403, 1) //XY曲線顯示長(zhǎng)度
for i=0 to 720 step 1
add=500+i
SetData(i, "Local HMI", LW, add, 1) //X軸資料賦值,從500單元開始,賦值0到720
next i
add=day*1440+360 //從早上6點(diǎn)開始,單元地址加6*60=360偏置量
for i=0 to 720 step 1
GetData(z, "Local HMI", RW_A, add, 1) //從RW_A讀取功率值
add=add+1
add1=i+1300
SetData(z, "Local HMI", LW, add1, 1) //Y軸資料賦值,從1300單元開始
next i
end macro_command
進(jìn)行相應(yīng)按鍵觸摸后執(zhí)行該條宏指令,寫入顯示控制地址內(nèi)容為3(清除原曲線,顯示新曲線),曲線長(zhǎng)度為720(12*60),X軸資料從500開始,內(nèi)容依次為0到720,Y軸資料從1300開始,內(nèi)容依次為從早6點(diǎn)到晚18點(diǎn)的功率數(shù)據(jù)。
XY曲線顯示配置方式如下:
四:觸摸屏通訊設(shè)計(jì)
光伏并網(wǎng)逆變器運(yùn)行時(shí)的實(shí)時(shí)參數(shù)、狀態(tài)等要及時(shí)傳輸?shù)接|摸屏上進(jìn)行計(jì)算、顯示、記錄、報(bào)警等,通訊設(shè)計(jì)采用RS232,比特率為9600,因?yàn)楣夥孀兤髦骺刂破鞑捎肨I公司TMS320F2812 數(shù)字處理器,觸摸屏采用MODBUS RTU (Adjustable)通訊協(xié)議,系統(tǒng)參數(shù)設(shè)置如下。
觸摸屏獲取逆變器數(shù)據(jù)采用定時(shí)數(shù)據(jù)傳輸模塊,設(shè)置如下,1秒定時(shí)進(jìn)行數(shù)據(jù)讀取逆變器單元0開始的12個(gè)單元,逆變器實(shí)時(shí)運(yùn)行數(shù)據(jù)保存在LW100連續(xù)的12個(gè)地址單元中。
光伏并網(wǎng)逆變器在需要和上位機(jī)進(jìn)行并網(wǎng)發(fā)電監(jiān)控時(shí),采用458總線通訊,主從方式,觸摸屏作為MODBUS Server設(shè)備。根據(jù)設(shè)置的站號(hào)進(jìn)行區(qū)分。當(dāng)上位機(jī)發(fā)出讀取逆變器運(yùn)行數(shù)據(jù)命令,符合觸摸屏站號(hào)時(shí),觸摸屏返回相應(yīng)單元的內(nèi)容。完成數(shù)據(jù)傳輸,實(shí)現(xiàn)光伏電站的監(jiān)控功能。系統(tǒng)參數(shù)設(shè)置
五:結(jié)束語(yǔ)
本系統(tǒng)采用WEINVIEW MT8100I觸摸顯示屏,實(shí)現(xiàn)了和DSP數(shù)字信號(hào)處理器的實(shí)時(shí)通訊。圖文并茂的顯示了并網(wǎng)逆變器運(yùn)行的各個(gè)參數(shù)和狀態(tài),曲線坐標(biāo)顯示了逆變器的功率參數(shù)和其趨勢(shì)效果圖。大容量的數(shù)據(jù)存儲(chǔ)功能,保存了逆變器詳細(xì)的歷史運(yùn)行數(shù)據(jù)。靈活、多樣的通訊接口方便實(shí)現(xiàn)光伏并網(wǎng)電站的監(jiān)控。觸摸屏可靠、穩(wěn)定的運(yùn)行,方便、靈活的操作,大大提高并網(wǎng)逆變器產(chǎn)品的市場(chǎng)競(jìng)爭(zhēng)力,取得了良好的社會(huì)效益和經(jīng)濟(jì)效益。