WIKA 230.15-851
帶UHP開關觸點 簧片觸點 不銹鋼電接點壓力表
Bourdon tube pressure gauges with switch contacts
UHP, stainless steel version
Model 230.15 with reed contact model 851.3
Bourdon tube pressure gauge with reed contact, UHP Model 230.15.2"
Applications
For gaseous and liquid, also aggressive media for demanding high purity applications, also in aggressive ambience
Suitable for all UHP (Ultra High Purity) applications
Semiconductor and flat panel industry
Gas distribution systems, medical gases
Hook-up application
Special features
Built-in electrical switch contact (reed contact)
VCR® compatible pressure connection threads
Helium leak tested
Electropolished case
Process connection surface finish Ra ≤ 0.25 μm
Debion
Nominal size
2"
Accuracy class
Grade A to ASME B40.1
Scale ranges
0 ... 4 to 0 ... 400 bar (0 ... 60 to 0 ... 6000 psi)
or all other equivalent vacuum or combined pressure and vacuum ranges
Pressure limitation
Steady: 3/4 x full scale value
Short time: full scale value
Operating temperature
Ambient: -20 ... +60 °C
Medium: +100 °C maximum
Temperature effect
When the temperature of the measuring system deviates from the reference temperature (+20 °C):
max. ±0.4 %/10 K of full scale value
Ingress protection
IP 54 per EN 60529 / lEC 529
Standard version
Process connection
Stainless steel 316L, lower mount (LM) or back mount, VCR® compatible threaded connection optionally:
with union nut (female)
with male nut
or with male thread 9/16-18 UNF fixed
Male thread ¼ NPT
Pressure element
Stainless steel 316L, C-type
Measuring system in crevice free design
Leak tightness: leak rate ≤ 10-9 mbar · l / s
Test b: helium mass spectrometry
Movement
Stainless steel
Dial
Aluminium, white, black lettering
Pointer
Aluminium, black
Case
Stainless steel, electropolished
Window
Polycarbonate,screw-fitted on case (twist lock)
Cleaning
Specially cleaned per SEMI standard
Switch contact
Reed contact model 851.3; the switching function is identified by the index 3; 851.3 = the contact switches(change-over contact)
Adjustment of switch point
In order to adjust the switch point, the instrument has to be disconnected from the voltage supply and the b has to be unscrewed. The switches are set via the mark pointer on the dial's circumference. The set value of the switch point is adjustable up to 80 % of the scale range.
Electrical load
max. switching voltage: DC / AC 24 V
max. contact rating: 10 W
max. current: 0.5 A
Electrical connection via cable gland
M8 x 1.25, cable outlet 3 m long, conductor cross section 0.14 mm2, flying leads, the terminal assignment is stated on the pressure gauge's connection plate
Options
Other process connection
Electrical connection via miniature connector (Binder connector M8 x 1)
Dual scale
Dimensions in mm
Standard version
Ordering inbation
Model / Nominal size / Scale range / Connection size / Connection b / Options
歡迎致電咨詢訂WIKA 230.15-851 帶UHP開關觸點 簧片觸點 不銹鋼電接點壓力表
電話:010-51669912 56291930 15910733293
傳真:010-51669912
QQ:823377546 1491421115 2636968574
公司官網(wǎng):http://www.zoriver.cn http://www.zoriver.com.cn