一、絕緣套管
1.產(chǎn)品概述(General Debion)
型號含義
(1) 型號含義
(2) 產(chǎn)品標(biāo)準(zhǔn):本產(chǎn)品性能符合GB4019-88標(biāo)準(zhǔn)。
(Executive stand:GB4109-88.)
(3) 用途:本系列套管為環(huán)氧樹脂APG工藝壓力凝膠成型結(jié)構(gòu),它適用于額定電壓為12KV、35KV及以下成套設(shè)備中,作為絕緣隔離和聯(lián)接過度用。
(Purpose:Tish series bushing is bed by epoxy resin with APG technics,it isused for insulation and connection transition of completes with rated voltage of 12KV,35KV and below.)
(4) 結(jié)構(gòu)簡介:套管耐污及潮濕,無需特別維護(hù),只需定期地清楚表面污物。安裝時,母排從中穿過。
(Structure:The busing is anti-pollution,moisture resisture and maintenance free,it only needs to clean the dietiness on surface at interval time.The bus is put through during installation.)
2.使用條件(Operation Condition)
(1) 戶內(nèi)裝置
(Indoor installation)
(2) 海拔高度不超過1000M
(Altitude:≤1000m;)
(3) 周圍氣溫+40℃~5℃;
(Ambient temperature:+40℃~5℃;)
(4) 當(dāng)空氣溫度+20℃時,相對濕度布超過85%
(The relative humidity shall not be more than 85%at+20℃ ambient temperature;)
(5) 無嚴(yán)重影響觸頭盒絕緣的氣體、蒸汽、灰塵及其它性和腐蝕介質(zhì)的場所。
(NO gas ,wapor or dust that may severely affect the insulation of contact box,no explosive or corrosive substance.)
3.產(chǎn)品規(guī)格及技術(shù)參數(shù)(Specification & Technical Parameter)
(1) 額定電壓:0、35KV;
(Rate voltage:10、35KV;)
(2) 最高電壓:12、40.5KV;
(Maximum voltage:12、40.5KV;)
(3) 應(yīng)能承受工頻耐壓(有效值)42KV、95KV、5min;雷電沖擊耐壓電壓(峰值):75KV、185KV(注:95KV/185KV為35KV套管試驗(yàn)值
(Power frequency withstand voltage (effective value) :42KV、95KV、5min;lightning impulse withstand voltage (peakval-ue) :75KV、185KV (Note:95KV/185KV is test value of 35KV bushing) )
4.套管外形及安裝尺寸。(See attached figure for installation dimension of bushing.)
180x110-194套管
歐式穿墻套管
套管100X145X218
套管128-100X100-246
套管140X200-197
套管140X200X230
套管152X152X260
套管210-125X125-233
二、陶瓷穿墻套管
型號 |
額定電壓KV |
額定電流A |
CB、CLB戶內(nèi)銅、鋁排穿墻套管 |
6,10,20,35 |
200、400、600、1000 |
CWB、CWLB戶外銅、鋁排穿墻套管 |
6,10,20,35 |
1500、2000、3000、3150 |
三、高壓穿墻套管
高壓穿墻套管CWB-35/630A
高壓穿墻套管CWWL-20/3000A
高壓穿墻套管CWC-10/2000A
高壓穿墻套管CWWC-20/1000A
高壓穿墻套管CB-10/200-630A
高壓穿墻套管CWC-10/2000A