Active Line Connection Modules?2 comprise a Line Connection Module, an Active Interface Module in chassis?2 bat and an Active Line Module in chassis?2 bat installed in a cabinet system. They can supply motoring energy to the DC b and return regenerative energy to the line supply.
The Active Line Connection Module?2 contains the line-side infeed via main switch and circuit breaker and pre-charging circuit. It connects the line-side supply network and the Active Line Module in chassis?2 bat. It is equipped as standard with a radio interference suppression filter according to EN 61800-3 Category C3.
Active Line Connection Modules?2 generate a controlled DC voltage that is kept consistent regardless of fluctuations in the line voltage (the line voltage must lie within the permissible tolerances).
In the factory setting, the DC voltage is regulated to 1.5 times the rms value of the nominal voltage of the distribution system.
Active Line Connection Modules draw a virtually sinusoidal current from the supply system and cause virtually no line harmonics.
Active Line Connection Modules are suitable for connection to supply systems grounded at the neutral point (TN, TT) and non-grounded (IT) supply systems. The following voltages and currents are available:
Line voltage |
Rated infeed/regenerative feedback current |
Rated power |
---|---|---|
380 ... 480 V 3 AC |
560 ... 1405 A |
355 ... 900 kW |
Active Line Connection Modules?2 always include an Active Interface Module in chassis?2 bat, which contains the associated Clean Power Filter and pre-charging circuit. The line filter that is included ensures compliance with the EMC requirements for the "second environment".
Active Line Connection Modules?2 are available for installing the Motor Modules to the right (article number "...RE0") and for installing the Motor Modules to the left (article number "...LE0"). The Line Connection Module with the line connection is installed directly next to the Active Interface Module.
Depending on the b current, the following versions are available:
The power rating can be increased by connecting Active Line Connection Modules?2 in parallel. You must observe the following rules:
For additional inbation, please refer to the SINAMICS Low Voltage Engineering Manual.
Connection example of an Active Line Connection Module?2 (Line Connection Module)
Connection example of an Active Line Connection Module?2 (Active Interface Module in chassis?2 bat and Active Line Module in chassis?2 bat)
Line voltage 380 ... 480 V 3 AC |
Active Line Connection Modules?2 |
||||
---|---|---|---|---|---|
|
|
6SL3731-7TE35-6RE01) |
6SL3731-7TE36-4RE01) |
6SL3731-7TE37-5RE01) |
6SL3731-7TE38-4RE01) |
|
|
6SL3731-7TE35- 6LE01) |
6SL3731-7TE36-4LE01) |
6SL3731-7TE37-5LE01) |
6SL3731-7TE38-4LE01) |
Rated power |
|
|
|
|
|
|
kW |
355 |
400 |
450 |
500 |
|
kW |
300 |
350 |
400 |
450 |
|
hp |
500 |
550 |
650 |
700 |
|
hp |
400 |
500 |
550 |
650 |
DC b current |
|
|
|
|
|
|
A |
630 |
710 |
835 |
940 |
|
A |
571 |
649 |
760 |
854 |
|
A |
857 |
974 |
1140 |
1281 |
Infeed/regenerative feedback current |
|
|
|
|
|
|
A |
560 |
635 |
745 |
840 |
|
A |
773 |
878 |
1028 |
1155 |
Pulse frequency |
kHz |
4 |
4 |
4 |
4 |
Current demand |
|
|
|
|
|
|
A |
1.5 |
1.5 |
1.5 |
1.5 |
|
A |
4.1 |
4.1 |
4.1 |
4.1 |
DC b capacitance |
|
|
|
|
|
|
μF |
16450 |
16450 |
18800 |
18800 |
|
μF |
250000 |
250000 |
250000 |
250000 |
Power loss, max. 3) |
|
|
|
|
|
|
kW |
12.14 |
12.65 |
16.38 |
17.32 |
|
kW |
12.14 |
12.65 |
16.38 |
17.32 |
Cooling air requirement |
m3/s (ft3/s) |
1.3 (45.9) |
1.3 (45.9) |
1.3 (45.9) |
1.3 (45.9) |
Sound pressure level LpA 4) (1 m) at 50/60 Hz |
dB |
75/75 |
75/75 |
75/75 |
75/75 |
Line supply connection L1, L2, L3 |
|
4 x M12 |
4 x M12 |
10 x M12 |
10 x M12 |
|
mm2 |
8 × 240 |
8 × 240 |
8 × 240 |
8 × 240 |
PE/GND connection |
|
PE bar |
PE bar |
PE bar |
PE bar |
|
mm2 |
600 |
600 |
600 |
600 |
|
mm2 |
240 |
240 |
240 |
240 |
Cable length, max. 5) Shielded/unshielded |
m (ft) |
3900/5850 (12795/19193) |
3900/5850 (12795/19193) |
3900/5850 (12795/19193) |
3900/5850 (12795/19193) |
Degree of protection (standard version) |
|
IP20 |
IP20 |
IP20 |
IP20 |
Dimensions (standard version) |
|
|
|
|
|
|
mm (in) |
1600 (63.0) |
1600 (63.0) |
1600 (63.0) |
1600 (63.0) |
|
mm (in) |
2200 (86.6) |
2200 (86.6) |
2200 (86.6) |
2200 (86.6) |
|
mm (in) |
600 (23.6) |
600 (23.6) |
600 (23.6) |
600 (23.6) |
Weight, approx. (standard version) |
kg (lb) |
989 (2180) |
994 (2191) |
1191 (2626) |
1192 (2628) |
Frame size |
|
|
|
|
|
|
|
HL |
HL |
JL |
JL |
|
|
FS2 |
FS2 |
FS4 |
FS4 |
|
|
FS2 |
FS2 |
FS2+ |
FS2+ |
Rated short-circuit current according to IEC |
kA |
50 |
50 |
100 |
100 |
Minimum short-circuit current 6) |
kA |
18 |
18 |
2 |
2 |
1) Article number "...RE0": Motor Modules installed to the right, "...LE0": Motor Modules installed to the left.
2) The base-load current IL DC is based on a duty cycle of 115 % for 60 s or Imax DC for 5 s with a duty cycle duration of 300 s.
3) The specified power loss represents the maximum value at 100 % utilization. The value is lower under normal operating conditions.
4) Total sound pressure level of Active Interface Module and Active Line Module.
5) Total of all motor cables and DC b. Longer cable lengths for specific configurations are available on request. For additional inbation, please refer to the SINAMICS Low Voltage Engineering Manual. The cable lengths are valid for use in IT systems. When used in TN systems, the cable lengths are shortened to 30 % of the specified value. When used in the TN system and when operating with increased pulse frequency, you will obtain the permitted cable lengths upon request.
6) Current required for reliably triggering protective devices.
Line voltage 380 ... 480 V 3 AC |
Active Line Connection Modules?2 |
|||||
---|---|---|---|---|---|---|
|
|
6SL3731-7TE38-8RE01) |
6SL3731-7TE41-0RE01) |
6SL3731-7TE41-2RE01) |
6SL3731-7TE41-3RE01) |
6SL3731-7TE41-4RE01) |
|
|
6SL3731-7TE38-8LE01) |
6SL3731-7TE41-0LE01) |
6SL3731-7TE41-2LE01) |
6SL3731-7TE41-3LE01) |
6SL3731-7TE41-4LE01) |
Rated power |
|
|
|
|
|
|
|
kW |
560 |
630 |
710 |
800 |
900 |
|
kW |
500 |
560 |
630 |
710 |
800 |
|
hp |
800 |
900 |
1050 |
1150 |
1300 |
|
hp |
700 |
800 |
900 |
1000 |
1150 |
DC b current |
|
|
|
|
|
|
|
A |
1010 |
1100 |
1245 |
1415 |
1575 |
|
A |
915 |
1004 |
1131 |
1287 |
1431 |
|
A |
1373 |
1506 |
1697 |
1931 |
2147 |
Infeed/regenerative feedback current |
|
|
|
|
|
|
|
A |
900 |
985 |
1110 |
1260 |
1405 |
|
A |
1238 |
1358 |
1530 |
1740 |
1935 |
Pulse frequency |
kHz |
4 |
4 |
4 |
4 |
4 |
Current demand |
|
|
|
|
|
|
|
A |
1.5 |
1.5 |
1.5 |
1.5 |
1.5 |
|
A |
4.1 |
4.1 |
4.1 |
4.1 |
4.1 |
DC b capacitance |
|
|
|
|
|
|
|
μF |
25900 |
25900 |
25900 |
40800 |
40800 |
|
μF |
250000 |
250000 |
250000 |
250000 |
250000 |
Power loss, max. 3) |
|
|
|
|
|
|
|
kW |
17.70 |
18.55 |
19.62 |
23.9 |
26.5 |
|
kW |
17.70 |
18.55 |
19.62 |
23.9 |
26.5 |
Cooling air requirement |
m3/s (ft3/s) |
1.7 (60.0) |
1.7 (60.0) |
1.7 (60.0) |
1.7 (60.0) |
1.7 (60.0) |
Sound pressure level LpA 4) (1 m) at 50/60 Hz |
dB |
75/75 |
75/75 |
75/75 |
75/75 |
7575 |
Line supply connection L1, L2, L3 |
|
10 x M12 |
10 x M12 |
10 x M12 |
10 x M12 |
10 x M12 |
|
mm2 |
8 × 240 |
8 × 240 |
8 × 240 |
8 × 240 |
8 × 240 |
PE/GND connection |
|
PE bar |
PE bar |
PE bar |
PE bar |
PE bar |
|
mm2 |
600 |
600 |
600 |
600 |
600 |
|
mm2 |
240 |
240 |
240 |
240 |
240 |
Cable length, max. 5) Shielded/unshielded |
m (ft) |
3900/5850 (12795/19193) |
3900/5850 (12795/19193) |
3900/5850 (12795/19193) |
3900/5850 (12795/19193) |
3900/5850 (12795/19193) |
Degree of protection (standard version) |
|
IP20 |
IP20 |
IP20 |
IP20 |
IP20 |
Dimensions (standard version) |
|
|
|
|
|
|
|
mm (in) |
1800 (70.9) |
1800 (70.9) |
1800 (70.9) |
1800 (70.9) |
1800 (70.9) |
|
mm (in) |
2200 (86.6) |
2200 (86.6) |
2200 (86.6) |
2200 (86.6) |
2200 (86.6) |
|
mm (in) |
600 (23.6) |
600 (23.6) |
600 (23.6) |
600 (23.6) |
600 (23.6) |
Weight, approx. (standard version) |
kg (lb) |
1264 (2787) |
1345 (2965) |
1406 (3100) |
1509 (3326) |
1529 (3371) |
Frame size |
|
|
|
|
|
|
|
|
JL |
JL |
JL |
JL |
JL |
|
|
FS4 |
FS4 |
FS4 |
FS4 |
FS4 |
|
|
FS4 |
FS4 |
FS4 |
FS4+ |
FS4+ |
Rated short-circuit current according to IEC |
kA |
100 |
100 |
100 |
100 |
100 |
Minimum short-circuit current 6) |
kA |
2 |
2.5 |
2.5 |
3.2 |
3.2 |
1) Article number "...RE0": Motor Modules installed to the right, "...LE0": Motor Modules installed to the left.
2) The base-load current IL DC is based on a duty cycle of 115 % for 60 s or Imax DC for 5 s with a duty cycle duration of 300 s.
3) The specified power loss represents the maximum value at 100 % utilization. The value is lower under normal operating conditions.
4) Total sound pressure level of Active Interface Module and Active Line Module.
5) Total of all motor cables and DC b. Longer cable lengths for specific configurations are available on request. For additional inbation, please refer to the SINAMICS Low Voltage Engineering Manual. The cable lengths are valid for use in IT systems. When used in TN systems, the cable lengths are shortened to 30 % of the specified value. When used in the TN system and when operating with increased pulse frequency, you will obtain the permitted cable lengths upon request.
6) Current required for reliably triggering protective devices.