西門子6FC5357-0BB15-0AA0
【銷售態(tài)度】:質(zhì)量保證、誠信服務(wù)、及時到位
【產(chǎn)品規(guī)格】:全新原裝
【產(chǎn)品質(zhì)量】:貨期短,大量現(xiàn)貨
【產(chǎn)品價格】:薄利多銷 信譽(yù)好,口碑好,價格
銷售宗旨:失去一個客戶只要三秒,得到一個客戶的信任卻需要2-3個月,甚至更長。銷售只是起點,服務(wù)沒有終點,交易是小,做人是大,一旦成為客戶,便永遠(yuǎn)是朋友,被信任是一種快樂
90°小彎腰致所有相信我的客戶、
上海晉營自動化科技有限公司
聯(lián)系人:喬 靜
電 話:18221796961(同微信號)
傳 真:021-37605857
郵 箱:3548508227@qq.com
Q Q:3548508227
上海市松江區(qū)翔昆路150號
Debion |
Article No. |
---|---|
Inbligent Operator Panel IOP |
|
|
6SL3255-0AA00-4JA1 |
|
6SL3255-0AA00-4JC1 |
Operator Panel IOP Handheld |
6SL3255-0AA00-4HA0 |
Operator Panel BOP‑2 |
6SL3255-0AA00-4CA1 |
Door mounting kit for IOP/BOP‑2 |
6SL3256-0AP00-0JA0 |
Push-through mounting frame |
|
|
|
|
6SL3260-6AA00-0DA0 |
|
6SL3260-6AB00-0DA0 |
|
6SL3260-6AC00-0DA0 |
Memory card |
|
|
6SL3054-4AG00-2AA0 |
Brake Relay |
6SL3252-0BB00-0AA0 |
Safe Brake Relay |
6SL3252-0BB01-0AA0 |
PC inverter connection kit 2 |
6SL3255-0AA00-2CA0 |
Shield connection kits |
|
|
|
|
Supplied with the Power Modules, available as a spare part |
|
|
|
6SL3262-1AC00-0DA0 |
|
6SL3262-1AD00-0DA0 |
|
6SL3262-1AF00-0DA0 |
|
|
|
6SL3264-1EA00-0FA0 |
|
6SL3264-1EA00-0HA0 |
|
6SL3264-1EA00-0HB0 |
|
6SL3264-1EA00-0LA0 |
STARTER commissioning tool 2) on DVD‑ROM |
6SL3072-0AA00-0AG0 |
SINAMICS Startdrive commissioning tool 3) on DVD‑ROM |
6SL3072-4DA02-0XG0 |
西門子6FC5357-0BB15-0AA0
電 話:18221796961(同微信號)
1) Approved only for CU230P‑2 HVAC and CU230P‑2 DP Control Units with firmware version V4.6 and higher.
2) The STARTER commissioning tool is also available on the Internet at http://www.siemens。。com/starter
3) The SINAMICS Startdrive commissioning tool is also available on Internet athttps://support.industry.siemens.com/cs/document/68034568
Line-side power components
The following line-side power components are available for SINAMICS G120 standard inverters:
Line filters
With one of the additional line filters, the Power Module attains a higher radio interference class.
Line reactors
(only for PM240‑2 Power Modules, frame sizes FSA to FSC, and PM240 FSGX)
Line reactors smooth the current drawn by the inverter and thus reduce harmonic components in the line current. Through the reduction of the current harmonics, the thermal load on the power components in the rectifier and in the DC-b capacitors is reduced as well as the harmonic effects on the supply. The use of a line reactor increases the service life of the inverter.
Note:
A DC b reactor is integrated in the PM240‑2 Power Modules FSD to FSF and therefore no line reactor is required.
Recommended line-side power components
Furthermore, this is a recommendation for additional line-side components, such as fuses and circuit breakers (line-side components must be dimensioned in accordance with IEC standards).
Additional inbation about the line-side power components can be found in Catalogs LV 10, IC 10 and IC 10 AO as well as the Industry Mall.
DC b components
The following DC b components are available for the SINAMICS G120 standard inverters:
Braking resistors 電 話:18221796961(同微信號)
(for PM240 and PM240‑2 Power Modules only)
西門子6FC5357-0BB15-0AA0
Excess energy in the DC b is dissipated in the braking resistor. The braking resistors are designed for use with PM240 and PM240‑2 Power Modules. They are equipped with an integrated braking chopper (electronic switch). There is an optional plug-in Braking Module for frame size FSGX.
Braking Module
(for PM240 Power Modules, frame size FSGX only)
A Braking Module and the matching external braking resistor are required to bring drives with a PM240 Power Module, frame size FSGX, to a controlled standstill in the event of a power failure (e.g. emergency retrb or EMERGENCY STOP Category 1) or to limit the DC b voltage during a short period of generator operation. The Braking Module houses the power electronics and the associated control circuit.
Load-side power components
The following load-side power components are available for the SINAMICS G120 standard inverters. This means that during operation with output reactors or sine-wave filters, longer, shielded motor cables are possible and the motor service life can be extended:
Output reactors
(not for PM240-2 Power Modules, frame sizes FSD to FSF, as these have an integrated DC b reactor)
Output reactors reduce the rate of voltage rise (dv/dt) and the height of the current peaks, and enable longer motor cables to be connected.
Sine-wave filters
(not for PM240‑2 Power Modules)
Sine-wave filters limit the rate of voltage rise (dv/dt) and the peak voltages on the motor winding. Similar to an output reactor, they enable the connection of longer motor cables.
Additional options
Further selected supplementary products are available from Siemens Partners.
Please select “Drive Options” as the technology in the "Solution Partner Finder” :
Spare parts 電 話:18221796961(同微信號)
Spare parts kit for Control Units
The spare parts kit contains small parts for all variants of the following SINAMICS G120 Control Units:
Shield connection kits for PM240‑2 Power Modules
A shield connection kit is supplied as standard with PM240‑2 Power Modules in frame sizes FSA to FSF. This shield connection kit is also available as a spare part.
Replacement door for PM240 Power Modules, frame size FSGX
A complete replacement door can be ordered for the PM240 Power Module, frame size FSGX.
Terminal cover kits for frame sizes FSD to FSF
The terminal cover kit includes a replacement cover for the connecting terminals. Terminal cover kits which are suitable for the PM240‑2 and PM250 Power Modules are available.
Replacement connectors for PM240‑2 Power Modules
A set of connectors for the line feeder cable, braking resistor and motor cable can be ordered corresponding to the frame size of the PM240‑2 Power Module.
Fan units for PM240‑2 Power Modules
The fans of PM240‑2 Power Modules are designed for extra long service life. For special requirements, replacement fans are available that can be exchanged quickly and easily.
Replacement fans for PM240 and PM250 Power Modules
The fans of PM240 and PM250 Power Modules are designed for extra long service life. Replacement fans can be ordered for special applications.
西門子6FC5357-0BB15-0AA0
The following electronic configuring aids and engineering tools are available for the SINAMICS G120 standard inverters:
Drive Technology Configurator (DT Configurator) within the CA 01
The interactive catalog CA 01 – the offline Industry Mall of Siemens on DVD‑ROM – contains over 100 000 products with approximaby 5 million possible drive system product variants. The Drive Technology Configurator (DT Configurator) has been developed to facilitate selection of the correct motor and/or inverter from the wide spectrum of drives. It is integrated in Catalog CA 01 as an add-on on DVD‑ROM.
Online DT Configurator
In addition, the DT Configurator can be used on the Internet without requiring any installation. The DT Configurator can be found in the Siemens Industry Mall at the following address:
http://www.siemens。。com/dt-configurator
SIZER for Siemens Drives engineering tool
The SIZER for Siemens Drives engineering tool makes it easy to engineer the SINAMICS drive family. It provides support when selecting the hardware and firmware components necessary to implement a drive task. SIZER for Siemens Drives is designed to support configuring of the entire drive system.
You can find further inbation on the SIZER for Siemens Drives engineering tool in the chapter Engineering tools.
The SIZER for Siemens Drives engineering tool is available free on the Internet at
http://www.siemens。。com/sizer
STARTER commissioning tool
The STARTER commissioning tool allows menu-bed commissioning, optimization and diagnostics. Apart from the SINAMICS drives, STARTER is also suitable for MICROMASTER 4 devices.
You can find further inbation about the STARTER commissioning tool in the chapter Engineering tools.
Additional inbation about the STARTER commissioning tool is available on the Internet at
http://www.siemens。。com/starter
SINAMICS Startdrive commissioning tool
SINAMICS Startdrive is a tool for configuring, commissioning, and diagnosing the SINAMICS family of drives and is integrated into the TIA Portal. SINAMICS Startdrive can be used to implement drive tasks with the SINAMICS G110M, SINAMICS G120, SINAMICS G120C, SINAMICS G120D and SINAMICS G120P inverter series. The commissioning tool has been optimized with regard to user friendliness and consistent use of the TIA Portal benefits of a common working environment for PLC, HMI and drives.
You can find further inbation on the SINAMICS Startdrive commissioning tool in the chapter Engineering tools.
The SINAMICS Startdrive commissioning tool is available free on the Internet at
http://www.siemens。。com/startdrive
Drive ES engineering system
Drive ES is the engineering system that can be used to integrate the communication, configuration and data management functions of Siemens drive technology into the SIMATIC automation world easily, efficiently and cost-effectively. Two software packages are available for SINAMICS – Drive ES Basic and Drive ES PCS.
You can find further inbation about the Drive ES engineering system in the chapter Engineering tools.
Additional inbation about the Drive ES engineering system is available on the Internet at
http://www.siemens。。com/drive-es
Unless explicitly specified otherwise, the following technical specifications are valid for all the following components of the SINAMICS G120 standard inverters.
General technical specifications |
|
---|---|
Mechanical ambient conditions |
|
Long-term storage acc. to EN 60721‑3‑1 |
|
|
Class 1M2 |
|
Class 1M2 |
Transport acc. to EN 60721‑3‑2 |
|
|
Class 2M3 |
|
Class 2M2 |
Operation acc. to EN 60721‑3‑3 |
|
|
Class 3M1 |
|
Test Fc (sinusoidal) according to EN 60068‑2‑6
Deflection: 0.075 mm at 10 ... 57 Hz |
|
Test Ea (semi-sinusoidal) according to EN 60068‑2‑27
Acceleration: 49 m/s2 (5 × g) at 30 ms |
|
|
|
Test Fc according to EN 60068‑2‑6
Deflection: 0.075 mm at 10...58 Hz |
|
Test Ea according to EN 60068‑2‑27 Acceleration: 98 m/s2 (10 × g) at 20 ms |
Ambient conditions |
|
Protection class |
Class I (with protective conductor system) and class III (PELV) |
Touch protection |
For the intended purpose |
Permissible ambient and coolant temperature (air) during operation for line-side power components and Power Modules |
|
|
|
|
-10 ... +40 °C (14 ... 104 °F) without derating |
|
-20 ... +40 °C (-4 ... +104 °F) without derating |
|
0 ... 40 ℃ (32 ... 104 °F) without derating |
|
0 ... 40 °C (32 ... 104 °F) without derating |
|
|
|
-10 ... +50 °C (14 ... 122 °F) without derating |
|
-20 ... +50 °C (-4 ... +122 °F) without derating |
|
0 ... 50 °C (32 ... 122 °F) without derating |
|
0 ... 40 °C (32 ... 104 °F) without derating |
Permissible ambient and coolant temperature (air) during operation for Control Units and supplementary system components |
With CU230P‑2 HVAC and CU230P‑2 DP: -10 ... +60 °C (14 ... 140 °F) With CU230P‑2 PN: -10 ... +55 °C (14 ... 131 °F) With CU240E‑2 (without PN): -10 ... +55 °C (14 ... 131 °F) With CU240E‑2 PN and CU240E‑2 PN‑F:-10 ... +53 °C (14 ... 127.4 °F) With CU250S‑2: -10 ... +50 °C (14 ... 122 °F) With IOP/BOP‑2: 0 ... 50 °C (32 ... 122 °F) Derating of 3 K/1000 m (3281 ft) applies to Control Units as of an installation altitude of 1000 m (3281 ft) above sea level. |
Climatic ambient conditions |
|
|
Class 1K4 |
|
Class 2K4 |
|
Better than class 3K3 with regard to
|
Environmental class/harmful chemical substances |
|
|
Class 1C2 |
|
Class 2C2 |
|
Class 3C2 3) |
Organic/biological influences |
|
|
Class 1B1 |
|
Class 2B1 |
|
Class 3B1 |
Degree of pollution |
2 |
Certification for fail-safe versions |
|
Applies to Control Units of the CU240E‑2 and CU250S‑2 series. The values include Control Unit and Power Module.
Note: |
The PM240‑2 Power Modules, frame sizes FSD to FSF additionally offer STO acc. to IEC 61508 SIL 3 and EN ISO 13489‑1 PL e and Category 3. |
|
SIL 2 |
|
PL d and Category 3 |
Standards |
|
Compliance with standards |
UL 4), cUL 4), CE, C-Tick (RCM), SEMI F47 Additionally for PM240‑2 frame sizes FSD ... FSF: KCC, WEEE, RoHS, EAC |
CE marking |
According to Low-Voltage Directive 2006/95/EC |
EMC Directive acc. to EN 61800‑3 |
|
Interference immunity |
|
PM240‑2 Power Modules |
The Power Modules are tested according to the interference immunity requirements for environments according to Category C3 |
Interference emissions |
|
PM240‑2 Power Modules |
|
|
5) |
|
Observance of the limit values
|
|
Observance of the limit values according to Category C3 and C2 6) |
|
Observance of the limit values
|
PM240 Power Modules |
|
|
5) |
|
Observance of the limit values
|
PM250 Power Modules |
|
|
Observance of the limit values according to Category C3 and C2 6) |
|
Observance of the limit values
|
|
5) |
|
Observance of the limit values according to Category C3 and C2 6) |
1) In product packaging.
2) In transport packaging.
3) SIPLUS components for extreme requirements are available. Additional inbation is available on the Internet athttp://www.siemens.de/siplus-drives
4) Applies to all PM240‑2, PM240 and PM250 Power Modules with integrated line filter class A.
5) Non-filtered devices are designed for operation on IT systems or in conjunction with an RCD. The customer must provide suitable RI suppression equipment to ensure that these devices comply with the limits defined for Category C3 or C2.
6) Max. permissible cable lengths see section Power Modules → Integration.
Note:
The EMC product standard EN 61800-3 does not apply directly to a frequency inverter but to a PDS (Power Drive System), which comprises the complete circuitry, motor and cables in addition to the inverter. The frequency inverters on their own do not generally require identification according to the EMC Directive.
Compliance with standards
CE marking
The SINAMICS G120 inverters meet the requirements of the Low-Voltage Directive 2006/95/EC.
Low-Voltage Directive
The inverters comply with the following standards listed in the official journal of the EU:
UL listing
Inverter devices in UL category NMMS certified to UL and cUL, in compliance with UL508C. UL list numbers E121068 and E192450. This applies to all PM240, PM240‑2 and PM250 Power Modules with integrated line filter class A.
For use in environments with pollution degree 2.
See also on the Internet at
http://www.ul。。com
Machinery Directive
The inverters are suitable for installation in machines. Compliance with the Machinery Directive 2006/42/EC requires a separate certificate of conbity. This must be provided by the plant construction company or the organization marketing the machine.
EMC Directive
The following inbation applies to SINAMICS G120 frequency inverters from Siemens AG:
SEMI F47
SEMI F47 is an industry standard relating to the immunity to voltage dips. This includes the requirement that industrial equipment must be able to tolerate defined dips or drops of the line supply voltage. As a result, industrial equipment that fulfills this standard is more reliable and productive. In the SINAMICS G120 product family, the PM240, PM240‑2 and PM250 Power Modules fulfill the latest SEMI F47‑0706 standard. In the case of a voltage dip, defined in accordance with SEMI F47‑0607, these drives either continue to supply a defined output current, or using an automatic restart function, continue to operate as expected.