西門(mén)子PROFIBUS通訊電纜6XV183O-3EH1O
產(chǎn)品詳細(xì)信息: 使用fc電纜2 x 2可快速、簡(jiǎn)便地連接到工業(yè)以太網(wǎng) fc rj45 引出插座(10/100 mbit/s)
或工業(yè)以太網(wǎng)fc rj45 180/90°接頭上,節(jié)省時(shí)間,專(zhuān)用總線(xiàn)電纜,應(yīng)用靈活,雙層屏蔽電纜和一致的接
地方案,網(wǎng)絡(luò)的抗干擾能力強(qiáng),不含硅。
應(yīng)用范圍: 用于工廠(chǎng)車(chē)間中的結(jié)構(gòu)化布線(xiàn),專(zhuān)用于快速裝配,特別適用于汽車(chē)行業(yè)(如噴漆生產(chǎn)線(xiàn))
技術(shù)說(shuō)明: 電纜規(guī)格cat 5e特征阻抗,1-100 mhz時(shí)100 Ω ± 15 Ω絕緣電阻 500 mΩ km芯線(xiàn)絕緣pe 1.5
mm工作溫度-40 oc 到+70 oc運(yùn)輸/貯存溫度-40 oc 到 +70 oc允許張力≤ 150 n阻燃性能,符合標(biāo)準(zhǔn)ul 1685
(csa ft 4)認(rèn)證ul 和 ccc
上海晉營(yíng)自動(dòng)化科技有限公司銷(xiāo)售西門(mén)子千萬(wàn)余產(chǎn)品 盡新老顧客您來(lái)詢(xún)價(jià)訂貨采購(gòu),歡迎您來(lái)晉營(yíng)公司,謝謝您的光臨!您的合作是我最大的榮幸!Thank you very much!
上海晉營(yíng)自動(dòng)化科技有限公司
聯(lián)系人:邵澤春
電 話(huà):17317269055同微信號(hào)
傳 真:021-37605857
郵 箱:3117125529@qq.com
Q Q : 3117125529
6XV1830-3EH10
![]()
SIMATIC NET, PB FC TRAILING CABLE, PROFIBUS TRAILING CABLE MAX. ACCELERATION:4M/QS MIN. OF 3 MILL. BENDING CYCLES MIN. BENDING RADIUS: APPROX.120 MM, 2-WIRE SHIELDED, SOLD BY THE METER MAX. CONSEIGNMENT: 1000 M MIN. ORDERING QUANTITY: 20 M
|
捆綁銷(xiāo)售:
![]() ![]()
SCALANCE XB008 UNMANAGED INDUSTRIAL ETHERNET SWITCH FOR 10/100MBIT/S; WITH 8 X 10/100MBIT/S TWISTED PAIR- PORTS WITH RJ45-SOCKETS; FOR CONFIGURING SMALL STAR- AND LINE TOPOGRAPHIES; LED-DIAGNOSIS, IP20, 24 V DC POWER SUPPLY, MANUAL AVAILABLE AS DOWNLOAD
![]() ![]()
PC ADAPTER USB A2 USB-ADAPTER (USB V2.0) FOR CONNECTING A PG/PC OR NOTEBOOK TO SIMATIC S7 VIA PROFIBUS OR MPI USB CABLE 5M INCLUDED MPI-KABEL 0,3M CAN BE USED UNDER WINXP/VISTA/ WINDOWS 7 32/64BIT
![]() ![]()
SIMATIC NET, PB FC STANDARD CABLE, LAN CABLE TWO-WIRE, SHIELDED, SPECIAL DESIGN FOR RAPID INSTALLATION, MAX. CONSIGNMENT: 1000 M,
![]() ![]()
PB BUS CONNECTOR WITH AXIAL CABLE OUTLET F.INDUSTR. PC, SIMATIC OP, OLM; TRANSMISSION RATE 12 MBIT/S; TERMINATING RESISTOR WITH SEPARATING FUNCTION, METAL HOUSING
![]() ![]()
COMPACT SWITCH MODULE CSM 1277 CONNECTION SIMATIC S7-1200 AND UP TO 3 FURTHER IND. ETHERNET USERS WITH 10/100 MBIT/S UNMANAGED SWITCH, 4 RJ45 PORTS, EXT. 24V DC POWER SUPPLY, LED DIAGNOSTICS, S7-1200 MODULE INCL. ELECTRONIC MANUAL ON CD
|
為了構(gòu)建 PROFIBUS DP 網(wǎng)絡(luò),提供有不同類(lèi)型的電纜,可滿(mǎn)足不同類(lèi)型應(yīng)用的要求。一般地,應(yīng)該使用所列出的電纜。有關(guān)網(wǎng)絡(luò)組態(tài)的詳細(xì)信息,請(qǐng)參見(jiàn) PROFIBUS 網(wǎng)絡(luò)手冊(cè)。
UL 認(rèn)證
用于網(wǎng)絡(luò)電纜的 UL 列表(安全標(biāo)準(zhǔn))對(duì)于美國(guó)和加拿大市場(chǎng)尤為必需。根據(jù)電纜敷設(shè)在建筑物中位置來(lái)決定適當(dāng)?shù)恼J(rèn)證要求。這適用所有電纜,這些電纜從一個(gè)機(jī)器敷設(shè)到一遠(yuǎn)程控制柜,位于電纜架上并保護(hù)著建筑物。通過(guò) UL 認(rèn)證的電纜在其名稱(chēng)后面附加字母“GP”(通用)。
Ex認(rèn)證
用于本質(zhì)安全 PROFIBUS DP 應(yīng)用的電纜在其名稱(chēng)后面附加字母“IS”(本質(zhì)安全)
屏蔽的雙絞電纜,圓形截面
所有 PROFIBUS 總線(xiàn)電纜的特點(diǎn):
電纜類(lèi)型
全新的快速連接(FC)總線(xiàn)電纜為徑向?qū)ΨQ(chēng)設(shè)計(jì),可使用剝線(xiàn)工具。以此,可以快速、簡(jiǎn)便地安裝總線(xiàn)接頭。
不采用快速連接技術(shù)的總線(xiàn)電纜(取決于結(jié)構(gòu)類(lèi)型)
Article number |
6XV1830-0EH10 |
6XV1831-2A |
6XV1830-0JH10 |
6XV1830-0GH10 |
|
---|---|---|---|---|---|
Product type designation |
PROFIBUS FC Standard Cable GP |
PROFIBUS FC Standard Cable IS GP |
PROFIBUS FC Robust Cable |
PROFIBUS FC Food Cable |
|
Product debion |
Standard bus cable (2-core), sold by the meter, unassembled |
Standard bus cable for fast installation, sold by the meter, unassembled |
Special bus cable (2-core), sold by the meter, unassembled |
Bus cable (2-core), sold by the meter, unassembled |
|
Suitability for use |
Standard cable specially designed for fast, permanent installation |
Used for intrinsically safe distributed I/O systems for permanent installation |
For use in chemically and mechanically demanding environments |
For use in the food, beverages and tobacco industries |
|
Cable designation |
02YSY (ST) CY 1x2x0,64/2,55-150 VI KF 40 FR |
02YSY (ST) CY 1x2x0,64/2,55 BL KF40 FR |
02YSY (ST) C11Y 1x2x0,64/2,55-150 VI KF 40 FR |
02YSY (ST) C2Y 1x2x0,64/2,55-150 KF 40 |
|
Electrical data |
|
|
|
|
|
Damping ratio per length |
|
|
|
|
|
|
2.5 dB/km |
2.5 dB/km |
2.5 dB/km |
2.5 dB/km |
|
|
4 dB/km |
4 dB/km |
4 dB/km |
4 dB/km |
|
|
22 dB/km |
22 dB/km |
22 dB/km |
22 dB/km |
|
|
42 dB/km |
42 dB/km |
42 dB/km |
42 dB/km |
|
Impedance |
|
|
|
|
|
|
150 ? |
150 ? |
150 ? |
150 ? |
|
|
270 ? |
270 ? |
270 ? |
270 ? |
|
|
185 ? |
185 ? |
185 ? |
185 ? |
|
|
150 ? |
150 ? |
150 ? |
150 ? |
|
Relative symmetrical tolerance |
|
|
|
|
|
|
10 % |
10 % |
10 % |
10 % |
|
|
10 % |
10 % |
10 % |
10 % |
|
|
10 % |
10 % |
10 % |
10 % |
|
Loop resistance per length maximum |
110 m?/m |
110 m?/m |
110 m?/m |
110 m?/m |
|
Shield resistance per length maximum |
9.5 ?/km |
9.5 ?/km |
9.5 ?/km |
9.5 ?/km |
|
Insulation resistance coefficient |
|
16 000 G?·m |
|
|
|
Capacity per length at 1 kHz |
28.5 pF/m |
28.5 pF/m |
28.5 pF/m |
28.5 pF/m |
|
Operating voltage |
|
|
|
|
|
|
100 V |
80 V |
80 V |
80 V |
|
Mechanical data |
|
|
|
|
|
Number of electrical cores |
2 |
2 |
2 |
2 |
|
Design of the shield |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
|
Type of electrical connection FastConnect |
Yes |
Yes |
Yes |
Yes |
|
Core diameter |
|
|
|
|
|
|
|
0.64 mm |
|
|
|
Outer diameter |
|
|
|
|
|
|
0.65 mm |
0.64 mm |
0.65 mm |
0.65 mm |
|
|
2.55 mm |
2.55 mm |
2.55 mm |
2.55 mm |
|
|
5.4 mm |
5.4 mm |
5.4 mm |
5.4 mm |
|
|
8 mm |
8 mm |
8 mm |
8 mm |
|
Symmetrical tolerance of the outer diameter of cable sheath |
0.4 mm |
0.4 mm |
0.4 mm |
0.4 mm |
|
Material |
|
|
|
|
|
|
PE |
PE |
PE |
PE |
|
|
PVC |
PVC |
PVC |
PVC |
|
|
PVC |
PVC |
PUR (TPE-U) |
PE; Outer cover made of PE is especially suitable for the food processing industry |
|
Color |
|
|
|
|
|
|
red/green |
red/green |
red/green |
red/green |
|
|
Violet |
blue |
Violet |
Black |
|
Bending radius |
|
|
|
|
|
|
37.5 mm |
37.5 mm |
75 mm |
30 mm |
|
|
75 mm |
75 mm |
150 mm |
60 mm |
|
Tensile load maximum |
100 N |
100 N |
100 N |
100 N |
|
Weight per length |
80 kg/km |
80 kg/km |
71 kg/km |
67 kg/km |
|
Permitted ambient conditions |
|
|
|
|
|
Ambient temperature |
|
|
|
|
|
|
-40 ... +75 °C |
-40 ... +75 °C |
-40 ... +60 °C |
-40 ... +60 °C |
|
|
-40 ... +75 °C |
-40 ... +75 °C |
-40 ... +60 °C |
-40 ... +60 °C |
|
|
-40 ... +75 °C |
-40 ... +75 °C |
-40 ... +60 °C |
-40 ... +60 °C |
|
|
-40 ... +75 °C |
-40 ... +75 °C |
-40 ... +60 °C |
-40 ... +60 °C |
|
|
Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 |
Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 |
Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 |
Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 |
|
Burning behavior |
flame resistant according to IEC 60332-3-24 (Category C) and UL 1685 (CSA FT 4) |
flame resistant according to IEC 60332-3-24 (Category C) |
flame resistant according to IEC 60332-1 |
inflammable |
|
Chemical resistance |
|
|
|
|
|
|
oil resistant according to IEC 60811-2-1 (4 hours / 70°C) |
oil resistant according to IEC 60811-2-1 (4 h / 70°C) |
oil resistant according to IEC 60811-2-1 (7x24h/90°C) |
oil resistant according to IEC 60811-2-1 (4 h / 70°C) |
|
|
Conditional resistance |
Conditional resistance |
resistant |
Conditional resistance |
|
|
conditional resistance |
conditional resistance |
conditional resistance |
conditional resistance |
|
Radiological resistance to UV radiation |
resistant |
resistant |
resistant |
resistant |
|
Product properties, functions, components general |
|
|
|
|
|
Product feature |
|
|
|
|
|
|
No |
No |
No |
No |
|
|
Yes |
Yes |
Yes |
Yes |
|
Standards, specifications, approvals |
|
|
|
|
|
UL/ETL listing 300 V Rating |
Yes; c(UL)us, CMG / CL3 / Sun Res |
Yes; CMG / CL3 / Sun Res |
Yes; c(UL)us, CMX |
No |
|
UL/ETL style 600 V Rating |
Yes |
Yes |
No |
No |
|
Certificate of suitability |
|
|
|
|
|
|
Yes |
Yes |
Yes |
Yes |
|
|
Yes |
|
|
|
|
|
Yes |
Yes |
Yes |
Yes |
|
Marine classification association |
|
|
|
|
|
|
No |
No |
No |
No |
|
|
No |
No |
No |
No |
|
|
No |
No |
No |
No |
|
|
No |
No |
No |
No |
|
|
No |
No |
No |
No |
|
|
No |
No |
No |
No |
|
|
No |
No |
No |
No |
Article number |
6XV1830-3FH10 |
6XV1831-2K |
6XV1830-3EH10 |
6XV1831-2L |
|
---|---|---|---|---|---|
Product type designation |
PROFIBUS FC Ground Cable |
PROFIBUS FC Flexible Cable |
PROFIBUS FC Trailing Cable |
PROFIBUS FC Trailing Cable |
|
Product debion |
Special bus cable (2-core) with additional protective jacket, sold by the meter, unassembled |
Flexible bus cable (2-core), sold by the meter, unassembled |
Highly flexible bus cable (2-core), sold by the meter, unassembled |
Highly flexible bus cable (2-core), sold by the meter, unassembled |
|
Suitability for use |
Used for buried cables |
For occasionally moved machine parts |
Continuous motion control in a cable carrier |
Continuous motion control in a cable carrier |
|
Cable designation |
02YSY (ST) CY2Y 1x2x0,64/2,55-150 SW KF 40 |
02YH (ST) C11Y 1x2x0,65/2,56-150 LI KF40 FRNC FC VI |
02YY (ST) C11Y 1x2x0,65/2,56-150 LI KF 40 FR petrol |
02YY (ST) C11Y 1x2x0,65/2,56-150 LI KF 40 FR VT FC |
|
Electrical data |
|
|
|
|
|
Damping ratio per length |
|
|
|
|
|
|
2.5 dB/km |
3 dB/km |
3 dB/km |
3 dB/km |
|
|
4 dB/km |
4 dB/km |
4 dB/km |
4 dB/km |
|
|
22 dB/km |
25 dB/km |
25 dB/km |
25 dB/km |
|
|
42 dB/km |
49 dB/km |
49 dB/km |
49 dB/km |
|
Impedance |
|
|
|
|
|
|
150 ? |
150 ? |
150 ? |
150 ? |
|
|
270 ? |
270 ? |
270 ? |
270 ? |
|
|
185 ? |
185 ? |
185 ? |
185 ? |
|
|
150 ? |
150 ? |
150 ? |
150 ? |
|
Relative symmetrical tolerance |
|
|
|
|
|
|
10 % |
10 % |
10 % |
10 % |
|
|
10 % |
10 % |
10 % |
10 % |
|
|
10 % |
10 % |
10 % |
10 % |
|
Loop resistance per length maximum |
110 m?/m |
133 m?/m |
133 m?/m |
133 m?/m |
|
Shield resistance per length maximum |
9.5 ?/km |
15 ?/km |
14 ?/km |
14 ?/km |
|
Insulation resistance coefficient |
|
16 000 G?·m |
|
|
|
Capacity per length at 1 kHz |
28.5 pF/m |
28 pF/m |
28 pF/m |
28 pF/m |
|
Operating voltage |
|
|
|
|
|
|
80 V |
80 V |
80 V |
80 V |
|
Mechanical data |
|
|
|
|
|
Number of electrical cores |
2 |
2 |
2 |
2 |
|
Design of the shield |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
|
Type of electrical connection FastConnect |
Yes |
Yes |
Yes |
Yes |
|
Outer diameter |
|
|
|
|
|
|
0.65 mm |
0.67 mm |
0.67 mm |
0.67 mm |
|
|
2.55 mm |
2.56 mm |
2.56 mm |
2.56 mm |
|
|
5.4 mm |
5.4 mm |
5.4 mm |
5.4 mm |
|
|
10.8 mm |
8 mm |
8 mm |
8 mm |