Gammex Sono404小范圍模體,Gammex Sono404超聲質(zhì)量模體
Gammex Sono404小范圍模體,Gammex Sono404超聲質(zhì)量模體
在血管和心臟超聲波中提高QC測量的準(zhǔn)確性。
對最困難的情況進(jìn)行有效的測試和培訓(xùn)
確保所有傳感器和系統(tǒng)設(shè)置均在2至18 MHZ的整個臨床頻率范圍內(nèi)通過HE(高等效)Gel?專利測試
定期測試您的高頻傳感器,以確保準(zhǔn)確的患者測量
Gammex Sono404小范圍模體,Gammex Sono404超聲質(zhì)量模體今天在世界各地的乳房護(hù)理中心和超聲診斷部門使用。
他們繼續(xù)廣泛采用的原因是與超聲成像技術(shù)的發(fā)展保持同步,以測量小部件和腔內(nèi)超聲系統(tǒng)的圖像質(zhì)量。
Gammex Sono404小范圍模體,Gammex Sono404超聲質(zhì)量模體:
支持符合ACR,AIUM,ESTRO和其他質(zhì)量保證計劃的要求
與醫(yī)學(xué)物理學(xué)家一起設(shè)計,并包括密集的針腳目標(biāo),是測試高頻換能器的理想選擇
具有耐用可靠的HE Gel,具有近似線性響應(yīng)的衰減,頻率在2到18 MHz之間
提供頻率超過8 MHz的衰減響應(yīng),以支持代表人體組織的精確軸向分辨率和穿透深度
Gammex Sono404小范圍模體,Gammex Sono404超聲質(zhì)量模體
主要用于滿足血管和心臟超聲波應(yīng)用的特殊需求
特點(diǎn)緊密間距針目標(biāo),測試高頻率傳感器的理想選擇
包括HE凝膠,可以復(fù)興,以便您的幻像可以重新驗(yàn)證,以加強(qiáng)您的投資
支持符合ACR,AIUM,ESTRO和其他質(zhì)量保證計劃的要求
衰減系數(shù)3: | 0.5或0.7dB / cm / MHz |
頻率衰減的變化1,4: |
在0.7dB / cm / MHz下0.5dB / cm / MHz f1.1的f1.08 |
HE凝膠凝固點(diǎn): | <0 ° C |
HE凝膠熔點(diǎn): | > 100 ° ? |
頻率范圍2: | 2 - 18 MHz |
聲音的速度: | 1540米/秒 |
消聲囊腫: | 10個囊,直徑1,2,3和7毫米 |
灰度目標(biāo): | 3個目標(biāo),-6,+ 6和+12 dB, |
水平幾何組: | 直徑7毫米 |
垂直幾何目標(biāo): | 3組,在1,3.5和6厘米深 |
水平幾何目標(biāo): | 17針,直徑0.1毫米,深度1至9厘米,間隔5毫米 |
死區(qū)檢測(交叉目標(biāo)): | 12針,1毫米直徑0.1毫米,10毫米間距1厘米深5厘米 |
特征 | Sono404 SCG | Sono404 SC | |
---|---|---|---|
組織模仿材料,獲得專利的多頻HE Gel ?: | ■ | ■ | |
掃描表面,專利復(fù)合膜: | ■ | ■ | |
統(tǒng)一評估: | ■ | ■ | |
幾何評估: | ■ | ■ | |
靈敏度評估: | ■ | ■ | |
決議評估: | ■ | ■ | |
滲透深度: | ■ | ■ | |
死區(qū)檢測: | ■ | ■ | |
諧波成像: | ■ | ■ | |
消聲囊腫: | ■ | ■ | |
灰度目標(biāo): | ■ |
Sono404? Phantoms
Enhance the accuracy of your QC measurements in vascular and cardiology ultrasounds.
Efficiently test and train for the most difficult cases
Ensure all transducers and system settings are fully tested across the entire clinical frequency range from 2 to 18 MHZ with patented HE (High Equivalency) Gel?
Test your high frequency transducers routinely to ensure accurate patient measurements
Sono404 Phantoms are in use today in breast care centers and diagnostic ultrasound departments around the world.
Their continued widespread adoption is attributed to a design that keeps pace with advancing ultrasound imaging technologies for measuring image quality of small parts and intra-cavity ultrasound systems.
Sono404 Phantoms:
Support compliance with ACR, AIUM, ESTRO and other QA program requirements
Have been designed with medical physicists, and include closely spaced pin targets, ideal for testing high frequency transducers
Feature durable and reliable HE Gel, with a near-linear-response of attenuation with with frequencies between 2 and 18 MHz
Offer response of attenuation with frequencies over 8 MHz to support accurate axial resolution and penetration depth representative of human tissue